{"id":8189,"date":"2026-09-28T07:21:13","date_gmt":"2026-09-28T12:21:13","guid":{"rendered":"https:\/\/saf.uy\/co\/?p=8189"},"modified":"2026-09-28T11:04:40","modified_gmt":"2026-09-28T16:04:40","slug":"proteccion-rayos-centrales-hidroelectricas","status":"publish","type":"post","link":"https:\/\/saf.uy\/co\/proteccion-rayos-centrales-hidroelectricas\/","title":{"rendered":"Protecci\u00f3n contra rayos en centrales hidroel\u00e9ctricas de Colombia: RETIE y SIPRA"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8189\" class=\"elementor elementor-8189\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d3c4bc e-flex e-con-boxed e-con e-parent\" data-id=\"7d3c4bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e33bb3 elementor-widget elementor-widget-text-editor\" data-id=\"3e33bb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Colombia combina alta actividad de rayos, relieve monta\u00f1oso, humedad y una matriz el\u00e9ctrica en la que la generaci\u00f3n hidr\u00e1ulica tiene un peso central. Las plantas se concentran especialmente en el noroeste y centro del pa\u00eds, donde centrales, peque\u00f1as centrales hidroel\u00e9ctricas, subestaciones y l\u00edneas atraviesan entornos con accesos complejos y condiciones meteorol\u00f3gicas muy variables.<\/p><p>En este contexto, la protecci\u00f3n debe tratar los efectos directos e indirectos del rayo. El RETIE vigente exige una evaluaci\u00f3n del nivel de riesgo para centrales de generaci\u00f3n construidas despu\u00e9s del 1 de mayo de 2005 y plantea un sistema integral de protecci\u00f3n, con componentes externos, puesta a tierra, medidas internas y mantenimiento.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-db05690 e-con-full e-flex e-con e-child\" data-id=\"db05690\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-363ca14 elementor-widget-divider--view-line_text elementor-widget-divider--element-align-left elementor-widget elementor-widget-divider\" data-id=\"363ca14\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t\t<h4 class=\"elementor-divider__text elementor-divider__element\">\n\t\t\t\tRESPUESTA DIRECTA\t\t\t\t<\/h4>\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2ca724 elementor-widget elementor-widget-text-editor\" data-id=\"c2ca724\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una central hidroel\u00e9ctrica en Colombia necesita un SIPRA basado en la evaluaci\u00f3n del riesgo. El dise\u00f1o integra terminales de captaci\u00f3n, bajantes, SPT, equipotencialidad, DPS, descargadores, apantallamiento, coordinaci\u00f3n de aislamiento, protecci\u00f3n de subestaciones, control y telecomunicaciones. El RETIE, la NTC 4552 y las especificaciones del operador deben verificarse en la edici\u00f3n vigente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e838ed elementor-widget elementor-widget-text-editor\" data-id=\"2e838ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Por qu\u00e9 el RETIE exige una evaluaci\u00f3n espec\u00edfica<\/h2><p>La evaluaci\u00f3n considera p\u00e9rdidas de vidas, interrupci\u00f3n de servicios esenciales, da\u00f1os a bienes y otros impactos relevantes. En una hidroel\u00e9ctrica, la indisponibilidad puede involucrar generaci\u00f3n, control de compuertas, servicios auxiliares, subestaci\u00f3n, comunicaciones y l\u00edneas asociadas. El resultado permite seleccionar medidas proporcionales al riesgo, en lugar de instalar equipos por costumbre o por un radio declarado.<\/p><p>El RETIE remite a la NTC 4552-2 o a procedimientos internacionales reconocidos como IEC 62305-2 cuando sean aplicables a las condiciones colombianas. La informaci\u00f3n local de densidad de rayos y la topograf\u00eda del sitio deben formar parte de los datos de entrada.<\/p><h2 class=\"codex-docx-preview_heading2\">\u00a0Componentes del SIPRA en una central hidroel\u00e9ctrica<\/h2><h3 class=\"codex-docx-preview_heading3\">Terminales de captaci\u00f3n y blindaje<\/h3><p>El sistema externo debe reducir la probabilidad de impactos sobre equipos y estructuras vulnerables. En edificios se utilizan terminales, mallas o elementos naturales; en patios y subestaciones se aplican m\u00e9todos de blindaje con m\u00e1stiles o cables de guarda. El RETIE indica que el dise\u00f1o debe emplear metodolog\u00edas reconocidas, como NTC 4552-3 o IEC 62305-3, y basarse en el m\u00e9todo electrogeom\u00e9trico.<\/p><h3 class=\"codex-docx-preview_heading3\">Bajantes y caminos en paralelo<\/h3><p>Las bajantes conducen la corriente desde la captaci\u00f3n hasta el SPT. Deben ser continuas, directas, protegidas contra da\u00f1o mec\u00e1nico y distribuidas para reducir chispas peligrosas y campos electromagn\u00e9ticos. En una central, tambi\u00e9n se estudian estructuras de concreto con refuerzo continuo, perfiles met\u00e1licos y conexiones entre edificios.<\/p><h3 class=\"codex-docx-preview_heading3\">Sistema de puesta a tierra<\/h3><p>El SPT integra mallas de generaci\u00f3n, subestaciones, estructuras, equipos y protecci\u00f3n atmosf\u00e9rica. Su dise\u00f1o debe controlar tensiones de paso, contacto y transferidas, adem\u00e1s de ofrecer caminos adecuados para fallas y corrientes de rayo. Se revisan resistividad, corrosi\u00f3n, uniones, electrodos, continuidad y cambios frente a inspecciones anteriores.<\/p><h3 class=\"codex-docx-preview_heading3\">Protecci\u00f3n contra sobretensiones<\/h3><p>Los descargadores protegen equipos de media y alta tensi\u00f3n, mientras los DPS limitan impulsos en baja tensi\u00f3n, corriente continua, control, datos y telecomunicaciones. La coordinaci\u00f3n evita que un dispositivo deje pasar una energ\u00eda superior a la soportable por el siguiente equipo. En zonas remotas se incluyen sensores, radioenlaces, c\u00e1maras, estaciones meteorol\u00f3gicas y alimentaci\u00f3n de emergencia.<\/p><h3 class=\"codex-docx-preview_heading3\">Equipotencialidad, apantallamiento y separaci\u00f3n<\/h3><p>La corriente del rayo genera diferencias de potencial y campos electromagn\u00e9ticos. Unir partes met\u00e1licas, controlar distancias de separaci\u00f3n, organizar rutas de cable, utilizar blindajes y establecer puntos de entrada reduce el riesgo de chispas y fallas electr\u00f3nicas. La fibra \u00f3ptica puede disminuir caminos conductivos, pero sus elementos met\u00e1licos y equipos terminales tambi\u00e9n deben evaluarse.<\/p><h2 class=\"codex-docx-preview_heading2\">Activos cr\u00edticos y medidas asociadas<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-49a6d3f eael-table-align-center eael-dt-th-align-left elementor-widget elementor-widget-eael-data-table\" data-id=\"49a6d3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-data-table.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style>\n\t\t\t@media (max-width: 767px) {\n\t\t\t   #eael-data-table-wrapper-49a6d3f.custom-responsive-option-enable .eael-data-table thead {\n                    display: none;\n               }\n               #eael-data-table-wrapper-49a6d3f.custom-responsive-option-enable .eael-data-table tbody tr td {\n                    float: none;\n                    clear: left;\n                    width: 100%;\n                    text-align: left;\n                    display: flex;\n                    align-items: center;\n                }\n\t\t\t}\n\t\t\t<\/style>\t\t<div class=\"eael-data-table-wrap custom-responsive-option-enable\" data-table_id=\"49a6d3f\" id=\"eael-data-table-wrapper-49a6d3f\" data-custom_responsive=\"true\">\n\t\t\t<table class=\"tablesorter eael-data-table center\" id=\"eael-data-table-49a6d3f\">\n\t\t\t    <thead>\n\t\t\t        <tr class=\"table-header\">\n\t\t\t\t\t\t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">Activo<\/span><\/th>\n\t\t\t        \t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">Riesgo Dominante<\/span><\/th>\n\t\t\t        \t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">Protecci\u00f3n prioritaria<\/span><\/th>\n\t\t\t        \t\t\t\t        <\/tr>\n\t\t\t    <\/thead>\n\t\t\t  \t<tbody>\n\t\t\t\t\t\t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCasa de M\u00e1quinas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpacto directo y circulaci\u00f3n por estructura\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCaptaci\u00f3n, bajantes, equipotencialidad y SPT\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tGeneradores y excitaci\u00f3n\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpulsos por potencia, control y auxiliares\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Descargadores, DPS, blindaje y coordinaci\u00f3n<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tTransformadores\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tOndas viajeras y falla de aislamiento\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Descargadores, coordinaci\u00f3n de aislamiento y tierra<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tSubestaci\u00f3n\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpacto sobre barras y equipos\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Blindaje electrogeom\u00e9trico, cables de guarda y SPT<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tSCADA y protecciones\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Sobretensiones, ruido y p\u00e9rdida de comunicaciones<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Zonificaci\u00f3n, DPS de se\u00f1al, fibra y equipotencialidad<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCompuertas y estaciones remotas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Exposici\u00f3n, l\u00edneas largas y acceso dif\u00edcil<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<p>Captaci\u00f3n localizada, SPT, se\u00f1al protegida y mantenimiento<\/p>\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t    <\/tbody>\n\t\t\t<\/table>\n\t\t<\/div>\n\t  \t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2885552 elementor-widget elementor-widget-text-editor\" data-id=\"2885552\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Protecci\u00f3n de subestaciones y l\u00edneas asociadas<\/h2><p>La subestaci\u00f3n requiere una evaluaci\u00f3n independiente dentro del proyecto general. El blindaje busca reducir impactos directos sobre barras, aisladores, transformadores e interruptores. La coordinaci\u00f3n de aislamiento relaciona los niveles soportados por los equipos con los descargadores y las ondas que llegan desde l\u00edneas. En Colombia, el RETIE vincula subestaciones exteriores con criterios de coordinaci\u00f3n de aislamiento y referencias como IEC 60071-2.<\/p><p>Las l\u00edneas pueden llevar una sobretensi\u00f3n hasta la central aunque el punto de impacto se encuentre lejos. Por eso se revisan cables de guarda, puesta a tierra de torres, desempe\u00f1o de aisladores, entradas a subestaci\u00f3n y ubicaci\u00f3n de descargadores. El art\u00edculo complementario sobre l\u00edneas desarrollar\u00e1 este tema con mayor detalle.<\/p><h2 class=\"codex-docx-preview_heading2\">Selecci\u00f3n de Franklin, PDC o PPDA<\/h2><p>La elecci\u00f3n debe realizarse despu\u00e9s de la evaluaci\u00f3n y de definir el m\u00e9todo de dise\u00f1o. El RETIE 2026 establece que sistemas de captaci\u00f3n no convencionales como ESE o cebado, Charge Transfer System y Dissipation Array System deben considerarse como bayonetas dentro del dise\u00f1o del sistema externo seg\u00fan la NTC 4552-3. En consecuencia, un radio comercial no reemplaza la demostraci\u00f3n del volumen protegido, las bajantes, el SPT ni las medidas internas.<\/p><p>SAF puede evaluar alternativas Franklin, PDC y PPDA dentro del alcance permitido por el proyecto. La propuesta debe identificar modelo, certificaciones, criterios de dise\u00f1o, soportes, materiales, ambiente, mantenimiento y relaci\u00f3n con el resto del SIPRA.<\/p><h2 class=\"codex-docx-preview_heading2\">Proceso recomendado para una central o PCH<\/h2><ol><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Definir alcance, fronteras, equipos cr\u00edticos y consecuencias de indisponibilidad.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Reunir planos, unifilares, estudios de tierra, registros de rayos, fallas y mantenimiento.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Realizar evaluaci\u00f3n de riesgo seg\u00fan RETIE y metodolog\u00eda reconocida.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Dise\u00f1ar protecci\u00f3n externa, SPT, equipotencialidad, DPS y coordinaci\u00f3n de aislamiento.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Revisar interfaces entre casa de m\u00e1quinas, subestaci\u00f3n, l\u00edneas y control.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Ejecutar montaje con protocolos HSE, trabajo en alturas y ventanas operativas.<\/li><li class=\"codex-docx-preview_listnumber codex-docx-preview-num-5-0\">Probar, documentar, inspeccionar y entregar manual de operaci\u00f3n y mantenimiento.<\/li><\/ol><h2 class=\"codex-docx-preview_heading2\">Clima, topograf\u00eda y log\u00edstica colombiana<\/h2><p>En Antioquia, Caldas, Cundinamarca, Santander, Tolima, Huila, Cauca y otras regiones con aprovechamientos hidr\u00e1ulicos pueden coexistir alta actividad de rayos, pendientes, vegetaci\u00f3n, lluvia intensa y accesos restringidos. La central puede incluir t\u00faneles, cavernas, estaciones remotas y l\u00edneas sobre terrenos dif\u00edciles. Estos factores influyen en corrosi\u00f3n, soportes, mantenimiento, comunicaciones y tiempo de respuesta.<\/p><p>XM se\u00f1ala que las plantas de generaci\u00f3n del sistema interconectado se concentran en el noroeste y centro del pa\u00eds. La versi\u00f3n colombiana debe reflejar ese contexto y evitar descripciones gen\u00e9ricas de un clima \u00fanico para todo el territorio.<\/p><h2 class=\"codex-docx-preview_heading2\">Inspecci\u00f3n, mantenimiento y evidencias<\/h2><p>El RETIE exige conexi\u00f3n el\u00e9ctrica permanente y verificaciones peri\u00f3dicas. La inspecci\u00f3n del SPT debe dejar evidencia de condiciones de conductores, corrosi\u00f3n, uniones, valores medidos, desviaciones, cambios, pruebas y registro fotogr\u00e1fico. En sistemas cr\u00edticos, la organizaci\u00f3n debe definir intervalos compatibles con su riesgo y operaci\u00f3n.<\/p><p>Tambi\u00e9n se revisan terminales, bajantes, descargadores, DPS, indicadores, cableados, documentaci\u00f3n y eventos. Una certificaci\u00f3n de producto no sustituye la verificaci\u00f3n del sistema instalado ni el plan de mantenimiento.<\/p><h2 class=\"codex-docx-preview_heading2\">Errores frecuentes en proyectos hidroel\u00e9ctricos<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee2054b elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"ee2054b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Instalar un terminal sin evaluaci\u00f3n del nivel de riesgo exigida por RETIE. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Usar el radio declarado de un equipo como \u00fanico m\u00e9todo de dise\u00f1o. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Separar el SPT del pararrayos de la malla principal sin estudio de potenciales. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Proteger tableros de potencia y omitir PLC, teleprotecci\u00f3n, datos y se\u00f1ales remotas.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">No coordinar el blindaje de la subestaci\u00f3n con descargadores y aislamiento. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Entregar certificados de producto sin planos, pruebas, registros ni manual del sistema.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e270312 elementor-widget elementor-widget-image\" data-id=\"e270312\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"563\" src=\"https:\/\/saf.uy\/co\/wp-content\/uploads\/hidroelectrica-itaipu-2.webp\" class=\"attachment-full size-full wp-image-8193\" alt=\"Central Hidroel\u00e9ctirca Itaip\u00fa\" srcset=\"https:\/\/saf.uy\/co\/wp-content\/uploads\/hidroelectrica-itaipu-2.webp 1000w, https:\/\/saf.uy\/co\/wp-content\/uploads\/hidroelectrica-itaipu-2-300x169.webp 300w, https:\/\/saf.uy\/co\/wp-content\/uploads\/hidroelectrica-itaipu-2-768x432.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0917bb elementor-widget elementor-widget-text-editor\" data-id=\"e0917bb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>An\u00e1lisis de SAF sobre Itaip\u00fa aplicado a centrales hidroel\u00e9ctricas<\/h2><p>SAF elabor\u00f3 un <strong>an\u00e1lisis t\u00e9cnico orientado a evaluar posibles mejoras en la protecci\u00f3n contra descargas atmosf\u00e9ricas de la Hidroel\u00e9ctrica de Itaip\u00fa<\/strong>, considerando una infraestructura de gran escala donde convergen generaci\u00f3n, transmisi\u00f3n, subestaciones, automatizaci\u00f3n y una extensa red de puesta a tierra.<\/p><p>Este antecedente resulta especialmente \u00fatil para Colombia, donde las centrales y PCH pueden operar en zonas de alta actividad de rayos y donde la protecci\u00f3n debe abordarse de manera integral, coordinando estructuras, sistema de puesta a tierra, protecci\u00f3n contra sobretensiones, control y continuidad operativa.<\/p><p>El estudio realizado sobre Itaip\u00fa contempl\u00f3 tanto las protecciones existentes como <strong>posibles alternativas de mejora<\/strong> en sectores cr\u00edticos, entre ellos torres de salida, p\u00f3rticos de subestaci\u00f3n, edificio de producci\u00f3n y conexiones a tierra. El enfoque es relevante para el contexto colombiano porque un terminal a\u00e9reo, un descargador o un DPS, considerados de forma aislada, no permiten evaluar por s\u00ed solos el comportamiento completo de la instalaci\u00f3n.<\/p><h3>Qu\u00e9 aporta este an\u00e1lisis al dise\u00f1o de un SIPRA<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7dd061 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"f7dd061\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Obliga a estudiar la exposici\u00f3n de l\u00edneas y torres junto con la protecci\u00f3n de la central, porque una falla puede ingresar desde fuera del per\u00edmetro del edificio.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Integra p\u00f3rticos, transformadores, casa de m\u00e1quinas, control y telecomunicaciones dentro de una misma estrategia de protecci\u00f3n y continuidad.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Refuerza la necesidad de caracterizar la puesta a tierra y de evitar soluciones aisladas cuando las estructuras est\u00e1n el\u00e9ctricamente interconectadas. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Permite evaluar tecnolog\u00edas PPDA y filtros de tierra dentro de un proyecto m\u00e1s amplio, sujeto al an\u00e1lisis de riesgo, la normativa y las especificaciones del operador.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5313284 elementor-widget elementor-widget-text-editor\" data-id=\"5313284\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Continuidad operativa como criterio de dise\u00f1o<\/h2><p>En una central de gran potencia, una descarga puede no causar un da\u00f1o permanente y aun as\u00ed generar disparos, ca\u00eddas de tensi\u00f3n o indisponibilidad temporal. Por este motivo, el an\u00e1lisis realizado por SAF sobre Itaip\u00fa tambi\u00e9n consider\u00f3 la interacci\u00f3n entre la protecci\u00f3n contra descargas atmosf\u00e9ricas y la respuesta autom\u00e1tica del sistema.<\/p><p>En Colombia, este criterio resulta especialmente relevante para centrales conectadas al SIN, donde el dise\u00f1o debe contemplar no solo la protecci\u00f3n f\u00edsica de los activos, sino tambi\u00e9n la continuidad del servicio, la coordinaci\u00f3n entre sistemas y la trazabilidad de las intervenciones realizadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5849f1d elementor-widget elementor-widget-text-editor\" data-id=\"5849f1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Servicios de SAF Colombia<\/h2><p>SAF ofrece <a href=\"https:\/\/saf.uy\/co\/servicios\/\">evaluaci\u00f3n, consultor\u00eda, ingenier\u00eda, provisi\u00f3n, montaje, mantenimiento y soluciones<\/a> Franklin, PDC, PPDA y filtros de tierra. En centrales hidroel\u00e9ctricas y PCH, el alcance puede incluir auditor\u00eda del SIPRA, revisi\u00f3n del SPT, protecci\u00f3n contra sobretensiones y recomendaciones por criticidad.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d5af58 content-align-cta-default elementor-widget elementor-widget-eael-cta-box\" data-id=\"5d5af58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-cta-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"eael-call-to-action cta-basic bg-lite cta-preset-1\">\n        <h2 class=\"title eael-cta-heading\">Solicite asesoramiento desde Medell\u00edn<\/h2><p>Env\u00ede ciudad o municipio, potencia, tipo de central, planos, subestaci\u00f3n asociada, l\u00edneas, SPT, equipos de control y antecedentes de tormentas. La oficina de SAF Colombia se encuentra en Medell\u00edn, con atenci\u00f3n a proyectos en diferentes regiones.<\/p><a href=\"https:\/\/saf.uy\/co\/contacto\/\" class=\"cta-button cta-preset-1  \">Cont\u00e1ctenos<\/a>\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c664cd0 elementor-widget elementor-widget-heading\" data-id=\"c664cd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preguntas Frecuentes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c6cc86 elementor-widget elementor-widget-n-accordion\" data-id=\"6c6cc86\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1130\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-1130\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfEl RETIE exige evaluaci\u00f3n de riesgo en una hidroel\u00e9ctrica? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1130\" class=\"elementor-element elementor-element-acc29cc e-con-full e-flex e-con e-child\" data-id=\"acc29cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1130\" class=\"elementor-element elementor-element-826bc60 e-flex e-con-boxed e-con e-child\" data-id=\"826bc60\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-784e224 elementor-widget elementor-widget-text-editor\" data-id=\"784e224\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed. El RETIE vigente indica que las centrales de generaci\u00f3n construidas despu\u00e9s del 1 de mayo de 2005 deben contar con evaluaci\u00f3n del nivel de riesgo frente a rayos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1131\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1131\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 es un SIPRA? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1131\" class=\"elementor-element elementor-element-f26741a e-con-full e-flex e-con e-child\" data-id=\"f26741a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1131\" class=\"elementor-element elementor-element-94fabb8 e-flex e-con-boxed e-con e-child\" data-id=\"94fabb8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1b37872 elementor-widget elementor-widget-text-editor\" data-id=\"1b37872\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Es el sistema integral que coordina protecci\u00f3n externa, SPT, equipotencialidad, protecci\u00f3n contra sobretensiones y medidas para personas, estructuras y equipos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1132\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1132\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfLa NTC 4552 aplica a centrales hidroel\u00e9ctricas? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1132\" class=\"elementor-element elementor-element-c0c44cc e-con-full e-flex e-con e-child\" data-id=\"c0c44cc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1132\" class=\"elementor-element elementor-element-13ea99b e-flex e-con-boxed e-con e-child\" data-id=\"13ea99b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b2ca79f elementor-widget elementor-widget-text-editor\" data-id=\"b2ca79f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El RETIE la utiliza como referencia para evaluaci\u00f3n y dise\u00f1o de protecci\u00f3n contra rayos, junto con normas internacionales reconocidas cuando resulten aplicables.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1133\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1133\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfUn PPDA puede dise\u00f1arse solo con su radio declarado? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1133\" class=\"elementor-element elementor-element-283f50a e-con-full e-flex e-con e-child\" data-id=\"283f50a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1133\" class=\"elementor-element elementor-element-6b5a6ad e-flex e-con-boxed e-con e-child\" data-id=\"6b5a6ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8d257d elementor-widget elementor-widget-text-editor\" data-id=\"d8d257d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No. El RETIE exige considerar los sistemas no convencionales como bayonetas dentro del dise\u00f1o seg\u00fan NTC 4552-3, adem\u00e1s de cumplir el resto del SIPRA.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1134\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1134\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfC\u00f3mo se protege una PCH? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1134\" class=\"elementor-element elementor-element-d2c90c1 e-con-full e-flex e-con e-child\" data-id=\"d2c90c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1134\" class=\"elementor-element elementor-element-e80ff94 e-flex e-con-boxed e-con e-child\" data-id=\"e80ff94\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ead7d76 elementor-widget elementor-widget-text-editor\" data-id=\"ead7d76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Con el mismo enfoque de riesgo, adaptado a escala, geometr\u00eda, conexi\u00f3n, personal, control, subestaci\u00f3n y consecuencias de falla. Peque\u00f1a potencia no significa riesgo inexistente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1135\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1135\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 debe medirse en el SPT? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1135\" class=\"elementor-element elementor-element-6387b09 e-flex e-con-boxed e-con e-child\" data-id=\"6387b09\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1135\" class=\"elementor-element elementor-element-0a08754 e-con-full e-flex e-con e-child\" data-id=\"0a08754\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4fa53c9 elementor-widget elementor-widget-text-editor\" data-id=\"4fa53c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La inspecci\u00f3n puede incluir equipotencialidad, resistencia, continuidad, condiciones de conductores y uniones, corrosi\u00f3n, cambios y tensiones relevantes seg\u00fan el dise\u00f1o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-1136\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-1136\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfSAF entrega documentaci\u00f3n para revisi\u00f3n RETIE? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1136\" class=\"elementor-element elementor-element-2d0c3b0 e-flex e-con-boxed e-con e-child\" data-id=\"2d0c3b0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-1136\" class=\"elementor-element elementor-element-f534f39 e-con-full e-flex e-con e-child\" data-id=\"f534f39\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49c5f95 elementor-widget elementor-widget-text-editor\" data-id=\"49c5f95\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El alcance puede incluir memorias, planos, fichas, pruebas e informe. Deben definirse desde la cotizaci\u00f3n las responsabilidades de dise\u00f1o, construcci\u00f3n e inspecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Protecci\u00f3n contra rayos en hidroel\u00e9ctricas de Colombia: evaluaci\u00f3n RETIE, SIPRA, puesta a tierra, DPS, subestaciones y mantenimiento. <\/p>\n","protected":false},"author":1,"featured_media":8190,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":"","_joinchat":[],"footnotes":""},"categories":[33,4],"tags":[289,291,283,282,288,290,284,287,285,286],"class_list":["post-8189","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-noticias","tag-descargadores-de-sobretension","tag-mantenimiento-de-sistemas-de-proteccion-contra-rayos","tag-pararrayos-para-centrales-hidroelectricas","tag-proteccion-contra-rayos-en-centrales-hidroelectricas","tag-proteccion-de-casa-de-maquinas","tag-proteccion-de-lineas-de-transmision","tag-proteccion-de-subestaciones-contra-rayos","tag-proteccion-de-transformadores-electricos","tag-puesta-a-tierra-en-centrales-hidroelectricas","tag-sobretensiones-en-centrales-hidroelectricas"],"acf":[],"_links":{"self":[{"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/posts\/8189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/comments?post=8189"}],"version-history":[{"count":11,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/posts\/8189\/revisions"}],"predecessor-version":[{"id":8224,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/posts\/8189\/revisions\/8224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/media\/8190"}],"wp:attachment":[{"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/media?parent=8189"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/categories?post=8189"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/saf.uy\/co\/wp-json\/wp\/v2\/tags?post=8189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}