{"id":8273,"date":"2026-09-28T11:12:20","date_gmt":"2026-09-28T14:12:20","guid":{"rendered":"https:\/\/saf.uy\/ar\/?p=8273"},"modified":"2026-09-28T19:42:58","modified_gmt":"2026-09-28T22:42:58","slug":"proteccion-contra-rayos-aerogeneradores","status":"publish","type":"post","link":"https:\/\/saf.uy\/ar\/proteccion-contra-rayos-aerogeneradores\/","title":{"rendered":"Protecci\u00f3n contra rayos en aerogeneradores de Argentina: c\u00f3mo reducir da\u00f1os y paradas"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8273\" class=\"elementor elementor-8273\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-52da4ab e-flex e-con-boxed e-con e-parent\" data-id=\"52da4ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4711f1c elementor-widget elementor-widget-text-editor\" data-id=\"4711f1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los aerogeneradores est\u00e1n entre las estructuras m\u00e1s expuestas de un parque e\u00f3lico: combinan gran altura, palas en movimiento, componentes de material compuesto, equipos electr\u00f3nicos sensibles y una conexi\u00f3n directa con redes el\u00e9ctricas extensas. Por eso, su protecci\u00f3n no depende de un pararrayos agregado despu\u00e9s de la instalaci\u00f3n. Debe estar integrada al dise\u00f1o de la turbina y coordinada con la puesta a tierra, los DPS, la red colectora, la subestaci\u00f3n y los procedimientos de mantenimiento.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-164ddd4 e-con-full e-flex e-con e-child\" data-id=\"164ddd4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-da43b4a elementor-widget-divider--view-line_text elementor-widget-divider--element-align-left elementor-widget elementor-widget-divider\" data-id=\"da43b4a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t\t<h4 class=\"elementor-divider__text elementor-divider__element\">\n\t\t\t\tRESPUESTA DIRECTA\t\t\t\t<\/h4>\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ffb2d elementor-widget elementor-widget-text-editor\" data-id=\"04ffb2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un aerogenerador se protege mediante receptores en las palas, caminos conductores controlados, uniones equipotenciales, desv\u00edo de corriente por la nacelle y la torre, puesta a tierra, DPS y medidas espec\u00edficas para sistemas el\u00e9ctricos y electr\u00f3nicos. El dise\u00f1o debe cumplir IEC 61400-24, las instrucciones del fabricante y las exigencias del proyecto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8deb59 elementor-widget elementor-widget-text-editor\" data-id=\"c8deb59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Por qu\u00e9 los aerogeneradores argentinos necesitan una estrategia espec\u00edfica<\/h2><p>Los parques e\u00f3licos argentinos se concentran principalmente en Patagonia, La Pampa y el sur de la provincia de Buenos Aires, aunque tambi\u00e9n existen proyectos en otras regiones. La altura de los equipos y la exposici\u00f3n en terrenos abiertos aumentan la probabilidad de interacci\u00f3n con tormentas. A esto se suman condiciones que modifican el envejecimiento de los componentes: fr\u00edo, hielo, r\u00e1fagas intensas, polvo, salinidad en \u00e1reas costeras y grandes amplitudes t\u00e9rmicas.<\/p><p>En un parque remoto, el costo de una falla no se limita a la pieza da\u00f1ada. Puede incluir detenci\u00f3n del aerogenerador, movilizaci\u00f3n de gr\u00faas, acceso a la pala, p\u00e9rdida de generaci\u00f3n, espera de repuestos y restricciones por clima. La gesti\u00f3n del riesgo debe considerar tanto la seguridad como la disponibilidad del activo.<\/p><h2 class=\"codex-docx-preview_heading2\">Qu\u00e9 partes puede da\u00f1ar un rayo<\/h2><h3 class=\"codex-docx-preview_heading3\">Palas y receptores<\/h3><p>Las palas suelen ser el punto de impacto m\u00e1s visible. Los receptores y conductores internos buscan captar y conducir la corriente sin que atraviese el laminado. Si el arco se desv\u00eda, pueden aparecer perforaciones, quemaduras, delaminaciones, humedad interna o da\u00f1os que crecen con la carga c\u00edclica. Una marca superficial no siempre revela el alcance real del defecto.<\/p><h3 class=\"codex-docx-preview_heading3\">Buje, nacelle y componentes mec\u00e1nicos<\/h3><p>La corriente debe cruzar partes m\u00f3viles y uniones mec\u00e1nicas. Cuando el camino previsto pierde continuidad o aumenta su impedancia, pueden producirse arcos en rodamientos, engranajes, ejes o uniones. El da\u00f1o puede ser inmediato o manifestarse despu\u00e9s como vibraci\u00f3n, picado, temperatura anormal o reducci\u00f3n de vida \u00fatil.<\/p><h3 class=\"codex-docx-preview_heading3\">Generador, convertidor y transformador<\/h3><p>Las sobretensiones pueden alcanzar bobinados, convertidores, fuentes, tableros y transformadores. La coordinaci\u00f3n de aislamiento y los DPS deben contemplar los niveles reales de tensi\u00f3n, la topolog\u00eda del fabricante, la longitud de cables y los puntos de entrada al sistema. Colocar un \u00fanico protector en la base de la torre no garantiza la protecci\u00f3n de todos los circuitos.<\/p><h3 class=\"codex-docx-preview_heading3\">Sensores, comunicaciones y SCADA<\/h3><p>Anem\u00f3metros, sensores de paso, controladores, redes de datos, fibra con elementos met\u00e1licos, c\u00e1maras y enlaces de telecomunicaciones pueden sufrir fallas por impulsos conducidos o inducidos. Estos da\u00f1os suelen generar paradas dif\u00edciles de diagnosticar y alarmas intermitentes, aun cuando la pala no muestre una lesi\u00f3n evidente.<\/p><h3 class=\"codex-docx-preview_heading3\">Torre, cimentaci\u00f3n y puesta a tierra<\/h3><p>La torre met\u00e1lica forma parte del camino de corriente, pero la continuidad de sus uniones, la conexi\u00f3n con la armadura y la dispersi\u00f3n en el terreno deben verificarse. Cambios en el suelo, corrosi\u00f3n, reparaciones, ampliaciones de la red colectora o uniones deficientes pueden alterar el comportamiento previsto.<\/p><h2 class=\"codex-docx-preview_heading2\">C\u00f3mo funciona la protecci\u00f3n integrada del aerogenerador<\/h2><h3 class=\"codex-docx-preview_heading3\">Captaci\u00f3n en las palas<\/h3><p>Los receptores se ubican de acuerdo con el dise\u00f1o de la pala y se conectan a conductores internos. Su geometr\u00eda, posici\u00f3n, materiales y ensayos son parte del modelo de aerogenerador. No deben perforarse, trasladarse ni complementarse con elementos improvisados sin autorizaci\u00f3n del fabricante.<\/p><h3 class=\"codex-docx-preview_heading3\">Conducci\u00f3n hasta la torre<\/h3><p>La corriente debe atravesar el sistema de paso, el buje, la nacelle y las interfaces giratorias por rutas previstas. Puentes, escobillas, anillos, conductores flexibles o elementos de equipotencialidad requieren inspecci\u00f3n porque el desgaste mec\u00e1nico y la contaminaci\u00f3n pueden aumentar la resistencia de contacto.<\/p><h3 class=\"codex-docx-preview_heading3\">Dispersi\u00f3n y equipotencialidad<\/h3><p>La cimentaci\u00f3n, los electrodos y la red del parque deben trabajar como un sistema coordinado. No se trata solo de obtener un n\u00famero bajo de resistencia: tambi\u00e9n importan la geometr\u00eda, la continuidad, las tensiones de paso y contacto, la distribuci\u00f3n de corriente y la interacci\u00f3n con cables, pantallas y subestaciones.<\/p><h3 class=\"codex-docx-preview_heading3\">Protecci\u00f3n contra sobretensiones<\/h3><p>Los DPS se seleccionan y coordinan para energ\u00eda, control, comunicaciones y servicios auxiliares. Deben ser compatibles con la tensi\u00f3n, el esquema de puesta a tierra, la corriente de cortocircuito, la capacidad de descarga y el nivel de soportabilidad de los equipos. Su estado debe poder inspeccionarse y registrarse.<\/p><h2 class=\"codex-docx-preview_heading2\">SAF E\u00f3lico: una propuesta de integraci\u00f3n sobre palas, nacelle y puesta a tierra<\/h2><p>SAF est\u00e1 desarrollando una arquitectura espec\u00edfica para aerogeneradores que busca intervenir sobre la acumulaci\u00f3n electrost\u00e1tica antes y durante la tormenta, sin limitar la protecci\u00f3n al punto donde finalmente podr\u00eda producirse una descarga. El concepto combina actuaci\u00f3n sobre las palas, protecci\u00f3n de la nacelle y medidas en la base de la torre, integradas con el sistema de puesta a tierra y con la ingenier\u00eda existente del aerogenerador.<\/p><p>El planteo parte de una condici\u00f3n conocida en este tipo de activos: las palas y estructuras elevadas pueden acumular carga a medida que aumenta el campo el\u00e9ctrico de la tormenta. La propuesta SAF E\u00f3lico busca mantener esa carga bajo control mediante una descarga continua de muy baja intensidad y reducir la saturaci\u00f3n electrost\u00e1tica del conjunto. Esta integraci\u00f3n debe dise\u00f1arse para cada modelo de turbina y coordinarse con el fabricante, IEC 61400-24 y la documentaci\u00f3n t\u00e9cnica del parque.<\/p><h3 class=\"codex-docx-preview_heading3\">C\u00f3mo se integra la soluci\u00f3n propuesta por SAF<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e8e498f elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"e8e498f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Palas y buje:<\/b> dispositivos SAF E\u00f3lico conectados al buje y al sistema de tierra para compensar cargas y limitar su acumulaci\u00f3n progresiva durante la tormenta.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Nacelle:<\/b> integraci\u00f3n de tecnolog\u00eda PPDA como parte del dise\u00f1o de protecci\u00f3n de la estructura y de la electr\u00f3nica, sujeta a la ingenier\u00eda espec\u00edfica del aerogenerador.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Base de la torre y puesta a tierra:<\/b> filtros Earth Stroke como capa complementaria frente a sobretensiones que pueden propagarse por el terreno y el sistema de tierra.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><b>Sistema completo:<\/b> coordinaci\u00f3n con receptores, conductores internos, equipotencialidad, DPS, red colectora y subestaci\u00f3n, evitando tratar cada componente de forma aislada.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6601609 elementor-widget elementor-widget-text-editor\" data-id=\"6601609\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 class=\"codex-docx-preview_heading3\">Estados progresivos de carga: el enfoque que gu\u00eda el desarrollo<\/h3><p>SAF representa el comportamiento del aerogenerador en cuatro etapas -sin tormenta, tormenta en desarrollo, tormenta m\u00e1xima y post tormenta- para comparar la evoluci\u00f3n de la carga electrost\u00e1tica con y sin su sistema. En el esquema conceptual de la empresa, el objetivo de la soluci\u00f3n integrada es sostener una disipaci\u00f3n controlada durante el crecimiento del campo el\u00e9ctrico y evitar que la estructura alcance un estado de alta acumulaci\u00f3n capacitiva. La imagen siguiente resume ese principio de dise\u00f1o; no reemplaza los ensayos, c\u00e1lculos ni validaciones requeridos para cada modelo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8c06ee elementor-widget elementor-widget-image\" data-id=\"f8c06ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores.jpeg\" data-elementor-open-lightbox=\"yes\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6ODI3NSwidXJsIjoiaHR0cHM6XC9cL3NhZi51eVwvYXJcL3dwLWNvbnRlbnRcL3VwbG9hZHNcL2Flcm9nZW5lcmFkb3Jlcy5qcGVnIn0%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores.jpeg\" class=\"attachment-full size-full wp-image-8275\" alt=\"instalaci\u00f3n de pararrayos\" srcset=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores.jpeg 1536w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores-300x200.jpeg 300w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores-1024x683.jpeg 1024w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores-768x512.jpeg 768w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" title=\"\">\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\"><\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccaba37 chica elementor-widget elementor-widget-text-editor\" data-id=\"ccaba37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><em>Esquema conceptual de SAF sobre estados progresivos de carga en aerogeneradores: comparaci\u00f3n del comportamiento previsto sin y con la soluci\u00f3n integrada.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3915562 elementor-widget elementor-widget-text-editor\" data-id=\"3915562\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 class=\"codex-docx-preview_heading3\">Desarrollo en Chubut y trabajo directo con el sector e\u00f3lico<\/h3><p>El equipo de SAF en Chubut, encabezado por la Ing. ambiental Josefina Aristarain, est\u00e1 a cargo del dise\u00f1o integrador de la tecnolog\u00eda SAF con aerogeneradores. En esta etapa, el equipo avanza en reuniones y evaluaciones t\u00e9cnicas con distintos actores del sector energ\u00e9tico, con el objetivo de analizar la integraci\u00f3n de esta propuesta en instalaciones e\u00f3licas y definir sus requisitos t\u00e9cnicos, operativos y de mantenimiento.<\/p><p>Este trabajo es especialmente relevante para Patagonia, donde la escala de los parques, la exposici\u00f3n al viento, las distancias log\u00edsticas y el costo de una parada prolongada vuelven cr\u00edtica cualquier mejora que pueda reducir intervenciones no planificadas. La participaci\u00f3n temprana de operadores y responsables de activos permite contrastar el desarrollo con condiciones reales de operaci\u00f3n antes de definir una soluci\u00f3n final.<\/p><h2 class=\"codex-docx-preview_heading2\">Protecci\u00f3n del parque m\u00e1s all\u00e1 de la turbina<\/h2><p>La IEC 61400-24 se ocupa del aerogenerador y del sistema e\u00f3lico, pero el sitio incluye edificios de operaci\u00f3n y mantenimiento, subestaciones, transformadores, torres meteorol\u00f3gicas, antenas, dep\u00f3sitos, estaciones de bombeo y l\u00edneas de comunicaci\u00f3n. Estas estructuras requieren su propia evaluaci\u00f3n y pueden regirse tambi\u00e9n por la serie IRAM 2184 \/ AEA 92305, basada en IEC 62305.<\/p><p>En este nivel SAF puede evaluar captaci\u00f3n, bajadas, equipotencialidad, puesta a tierra, DPS y mantenimiento. Los <a href=\"https:\/\/saf.uy\/ar\/pararrayos-franklin\/\">pararrayos Franklin<\/a>, PDC o inhibidores <a href=\"https:\/\/saf.uy\/ar\/pararrayos-inhibidor-zeus\/\">PPDA<\/a> solo deben incorporarse donde el an\u00e1lisis, la normativa y el responsable t\u00e9cnico los justifiquen. No sustituyen el sistema interno de las palas ni las exigencias del fabricante del aerogenerador.<\/p><h2 class=\"codex-docx-preview_heading2\">Normas y documentaci\u00f3n que deben revisarse<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdcbcf8 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"cdcbcf8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">IEC 61400-24:2019 con su Enmienda 1:2024, espec\u00edfica para protecci\u00f3n contra rayos de aerogeneradores y sistemas e\u00f3licos.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Manual, planos, boletines y criterios de mantenimiento del fabricante y del modelo instalado.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Serie IRAM 2184 \/ AEA 92305 para estructuras, riesgo, da\u00f1o f\u00edsico y sistemas el\u00e9ctricos o electr\u00f3nicos del resto del sitio.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Especificaciones del propietario, requisitos de conexi\u00f3n, seguridad el\u00e9ctrica y procedimientos de trabajo en altura.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Registros de impactos, alarmas, reparaciones, mediciones y modificaciones realizadas durante la vida del parque.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e51ad62 elementor-position-inline-start elementor-view-default elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"e51ad62\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon elementor-animation-pulse\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-exclamation-triangle\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tAdvertencia normativa\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tLas normas cambian y el alcance depende de la instalaci\u00f3n. Antes de publicar o ejecutar un proyecto debe verificarse la edici\u00f3n vigente y la autoridad competente. IEC 61400-24 no autoriza a modificar una pala ni una nacelle sin la validaci\u00f3n correspondiente.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-01c7eda elementor-widget elementor-widget-text-editor\" data-id=\"01c7eda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Cu\u00e1ndo inspeccionar el sistema<\/h2><p>La frecuencia debe definirse seg\u00fan el fabricante, el historial de tormentas, el ambiente, la criticidad y el plan de mantenimiento. Adem\u00e1s de las inspecciones programadas, conviene activar una revisi\u00f3n cuando el sistema de detecci\u00f3n registra un evento, aparecen alarmas, se observan da\u00f1os, se realiza una reparaci\u00f3n estructural o cambian conexiones de tierra, cables o equipos.<\/p><h3 class=\"codex-docx-preview_heading3\">Controles recomendados<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04c2d44 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"04c2d44\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Revisi\u00f3n visual y t\u00e9cnica de receptores, superficie de pala y zonas reparadas.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Verificaci\u00f3n de continuidad de caminos conductores seg\u00fan procedimientos del fabricante.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Inspecci\u00f3n de puentes, uniones, escobillas, anillos y conexiones equipotenciales.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Control de rodamientos y componentes mec\u00e1nicos cuando existan indicios de arco o impacto.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Lectura de indicadores, contadores de rayos, alarmas y registros SCADA.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Revisi\u00f3n de DPS, tableros, convertidores, transformadores y circuitos de comunicaciones.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Medici\u00f3n y evaluaci\u00f3n del sistema de puesta a tierra con m\u00e9todos compatibles con la configuraci\u00f3n del parque.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Informe fotogr\u00e1fico, trazabilidad de defectos y priorizaci\u00f3n de acciones.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a45b3c elementor-widget elementor-widget-text-editor\" data-id=\"2a45b3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Qu\u00e9 debe incluir una evaluaci\u00f3n t\u00e9cnica<\/h2><p>1. Identificaci\u00f3n de fabricante, modelo, potencia, a\u00f1o y configuraci\u00f3n del aerogenerador.<\/p><p>2. Planos de protecci\u00f3n contra rayos, rutas de corriente y puesta a tierra.<\/p><p>3. Historial de impactos, alarmas, paradas, da\u00f1os y reparaciones.<\/p><p>4. Revisi\u00f3n de palas, nacelle, torre, cimentaci\u00f3n y conexiones del parque.<\/p><p>5. Coordinaci\u00f3n de DPS y protecciones en energ\u00eda, control y telecomunicaciones.<\/p><p>6. Evaluaci\u00f3n de edificios, subestaci\u00f3n y estructuras auxiliares.<\/p><p>7. Plan de correcciones, mantenimiento, documentaci\u00f3n y seguimiento.<\/p><h2 class=\"codex-docx-preview_heading2\">C\u00f3mo puede intervenir SAF Argentina<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-434d3cf elementor-widget elementor-widget-image\" data-id=\"434d3cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"563\" src=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores04-w.webp\" class=\"attachment-full size-full wp-image-8281\" alt=\"rayos en parques e\u00f3licos\" srcset=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores04-w.webp 1000w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores04-w-300x169.webp 300w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/aerogeneradores04-w-768x432.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-318b001 elementor-widget elementor-widget-text-editor\" data-id=\"318b001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>SAF Argentina puede intervenir tanto en la protecci\u00f3n atmosf\u00e9rica general del parque como en el desarrollo integrador SAF E\u00f3lico para aerogeneradores. El alcance puede incluir evaluaci\u00f3n de riesgo, puesta a tierra, equipotencialidad, DPS, edificios auxiliares, subestaciones y, cuando el proyecto lo permita, el estudio de integraci\u00f3n sobre palas, buje, nacelle y base de torre. Toda intervenci\u00f3n sobre componentes propios de la turbina debe coordinarse con el fabricante y con los responsables t\u00e9cnicos del modelo.<\/p><p>Para una primera revisi\u00f3n conviene enviar ubicaci\u00f3n del parque, fabricante y modelo, cantidad de aerogeneradores, planos de puesta a tierra, subestaci\u00f3n, historial de rayos, fotograf\u00edas y descripci\u00f3n de fallas. La oficina de SAF Argentina se encuentra en la Ciudad de Buenos Aires y puede analizar proyectos de Patagonia, provincia de Buenos Aires, La Pampa y otras regiones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef13625 content-align-cta-default elementor-widget elementor-widget-eael-cta-box\" data-id=\"ef13625\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-cta-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"eael-call-to-action cta-basic bg-lite cta-preset-1\">\n        <h2 class=\"title eael-cta-heading\">Solicit\u00e1 una evaluaci\u00f3n del parque e\u00f3lico<\/h2><p>Una evaluaci\u00f3n temprana permite distinguir defectos urgentes de mejoras planificables. Complet\u00e1 el formulario de Argentina con la ubicaci\u00f3n, el modelo de aerogenerador y el problema observado para definir el alcance t\u00e9cnico adecuado.<\/p><a href=\"https:\/\/saf.uy\/ar\/contacto\/\" class=\"cta-button cta-preset-1  \">Cont\u00e1ctenos<\/a>\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1b09ec elementor-widget elementor-widget-heading\" data-id=\"c1b09ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preguntas Frecuentes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-206cb62 elementor-widget elementor-widget-n-accordion\" data-id=\"206cb62\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3390\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-3390\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfUn aerogenerador necesita un pararrayos convencional en la nacelle? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3390\" class=\"elementor-element elementor-element-b971119 e-con-full e-flex e-con e-child\" data-id=\"b971119\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3390\" class=\"elementor-element elementor-element-95b3124 e-flex e-con-boxed e-con e-child\" data-id=\"95b3124\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-293b7be elementor-widget elementor-widget-text-editor\" data-id=\"293b7be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No como una soluci\u00f3n aislada. El aerogenerador ya cuenta con una protecci\u00f3n integrada y ensayada. El desarrollo SAF E\u00f3lico contempla la posible integraci\u00f3n de PPDA en la nacelle dentro de una arquitectura m\u00e1s amplia que tambi\u00e9n considera palas, buje, puesta a tierra y sobretensiones. Cualquier incorporaci\u00f3n debe justificarse mediante ingenier\u00eda espec\u00edfica y coordinarse con el fabricante.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3391\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3391\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 pasa cuando un rayo impacta una pala? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3391\" class=\"elementor-element elementor-element-9ce105a e-con-full e-flex e-con e-child\" data-id=\"9ce105a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3391\" class=\"elementor-element elementor-element-c7a4509 e-flex e-con-boxed e-con e-child\" data-id=\"c7a4509\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f9b5d7f elementor-widget elementor-widget-text-editor\" data-id=\"f9b5d7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El sistema intenta recibir la descarga en un receptor y conducirla hacia tierra. Si el arco sale del camino previsto, puede da\u00f1ar el laminado, adhesivos, conductores o componentes internos. La inspecci\u00f3n debe evaluar m\u00e1s que la marca visible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3392\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3392\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfLa torre met\u00e1lica alcanza como puesta a tierra? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3392\" class=\"elementor-element elementor-element-db5ef93 e-con-full e-flex e-con e-child\" data-id=\"db5ef93\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3392\" class=\"elementor-element elementor-element-ddf76a4 e-flex e-con-boxed e-con e-child\" data-id=\"ddf76a4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1bfe609 elementor-widget elementor-widget-text-editor\" data-id=\"1bfe609\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La torre conduce corriente, pero necesita continuidad con la cimentaci\u00f3n y la red de tierra. Deben evaluarse uniones, geometr\u00eda, corrosi\u00f3n, tensiones y conexiones con cables y subestaciones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3393\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3393\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfCada cu\u00e1nto se inspecciona la protecci\u00f3n contra rayos? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3393\" class=\"elementor-element elementor-element-6361cb1 e-con-full e-flex e-con e-child\" data-id=\"6361cb1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3393\" class=\"elementor-element elementor-element-b83594e e-flex e-con-boxed e-con e-child\" data-id=\"b83594e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8900f1 elementor-widget elementor-widget-text-editor\" data-id=\"e8900f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La periodicidad la define el fabricante y el plan de mantenimiento. Tambi\u00e9n corresponde inspeccionar despu\u00e9s de impactos registrados, alarmas, da\u00f1os, reparaciones o cambios en el sistema.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3394\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3394\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfLos DPS protegen tambi\u00e9n SCADA y comunicaciones? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3394\" class=\"elementor-element elementor-element-c9b8d25 e-con-full e-flex e-con e-child\" data-id=\"c9b8d25\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3394\" class=\"elementor-element elementor-element-631da6c e-flex e-con-boxed e-con e-child\" data-id=\"631da6c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c21114a elementor-widget elementor-widget-text-editor\" data-id=\"c21114a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed, cuando se seleccionan para el tipo de circuito y se coordinan correctamente. Energ\u00eda, control, datos y telecomunicaciones requieren soluciones diferentes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3395\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3395\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 norma se usa en Argentina? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3395\" class=\"elementor-element elementor-element-042fcad e-flex e-con-boxed e-con e-child\" data-id=\"042fcad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3395\" class=\"elementor-element elementor-element-ef0b681 e-con-full e-flex e-con e-child\" data-id=\"ef0b681\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a0a623e elementor-widget elementor-widget-text-editor\" data-id=\"a0a623e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para el aerogenerador se toma como referencia IEC 61400-24 y los requisitos del fabricante. Para edificios y otras estructuras del parque se consideran IRAM 2184 \/ AEA 92305 y la normativa aplicable al proyecto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3396\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3396\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfSAF puede reparar una pala da\u00f1ada? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3396\" class=\"elementor-element elementor-element-aa8f84a e-flex e-con-boxed e-con e-child\" data-id=\"aa8f84a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3396\" class=\"elementor-element elementor-element-da686de e-con-full e-flex e-con e-child\" data-id=\"da686de\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-063afae elementor-widget elementor-widget-text-editor\" data-id=\"063afae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La reparaci\u00f3n de palas es un trabajo especializado que debe seguir el procedimiento del fabricante. SAF puede evaluar la protecci\u00f3n atmosf\u00e9rica y coordinar el diagn\u00f3stico con los especialistas correspondientes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-3397\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-3397\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 datos necesito para pedir un presupuesto? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3397\" class=\"elementor-element elementor-element-2edddda e-flex e-con-boxed e-con e-child\" data-id=\"2edddda\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-3397\" class=\"elementor-element elementor-element-14e150e e-con-full e-flex e-con e-child\" data-id=\"14e150e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fb076bc elementor-widget elementor-widget-text-editor\" data-id=\"fb076bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ubicaci\u00f3n, cantidad y modelo de aerogeneradores, planos, historial de impactos, fallas observadas, alcance requerido, restricciones de acceso y documentaci\u00f3n disponible.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>C\u00f3mo proteger aerogeneradores en Argentina frente a rayos: palas, nacelle, puesta a tierra, DPS, inspecci\u00f3n y normas t\u00e9cnicas.<\/p>\n","protected":false},"author":1,"featured_media":8277,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":"","_joinchat":[],"footnotes":""},"categories":[33,4],"tags":[279,273,280,272,278,274,276,275,281,277],"class_list":["post-8273","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-noticias","tag-mantenimiento-de-aerogeneradores","tag-pararrayos-para-aerogeneradores","tag-ppda-para-aerogeneradores","tag-proteccion-contra-rayos-en-aerogeneradores","tag-proteccion-de-palas-de-aerogeneradores","tag-proteccion-eolica-contra-rayos","tag-puesta-a-tierra-en-aerogeneradores","tag-rayos-en-parques-eolicos","tag-saf-eolico","tag-sobretensiones-en-aerogeneradores"],"acf":[],"_links":{"self":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/comments?post=8273"}],"version-history":[{"count":19,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8273\/revisions"}],"predecessor-version":[{"id":8306,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8273\/revisions\/8306"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/media\/8277"}],"wp:attachment":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/media?parent=8273"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/categories?post=8273"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/tags?post=8273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}