{"id":8250,"date":"2026-09-27T19:35:42","date_gmt":"2026-09-27T22:35:42","guid":{"rendered":"https:\/\/saf.uy\/ar\/?p=8250"},"modified":"2026-09-28T12:51:40","modified_gmt":"2026-09-28T15:51:40","slug":"proteccion-rayos-centrales-hidroelectricas","status":"publish","type":"post","link":"https:\/\/saf.uy\/ar\/proteccion-rayos-centrales-hidroelectricas\/","title":{"rendered":"Protecci\u00f3n contra rayos en centrales hidroel\u00e9ctricas de Argentina: gu\u00eda integral"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8250\" class=\"elementor elementor-8250\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-754bb30 e-flex e-con-boxed e-con e-parent\" data-id=\"754bb30\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e3aa6ba elementor-widget elementor-widget-text-editor\" data-id=\"e3aa6ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las centrales hidroel\u00e9ctricas re\u00fanen estructuras elevadas, grandes superficies met\u00e1licas, l\u00edneas de transmisi\u00f3n, equipos de alta potencia y sistemas electr\u00f3nicos sensibles. En ese entorno, un rayo puede causar da\u00f1os por impacto directo, sobretensiones conducidas o inducidas, diferencias de potencial y fallas que se propagan entre \u00e1reas conectadas.<\/p><p>La protecci\u00f3n no se resuelve colocando una sola punta sobre la casa de m\u00e1quinas. Requiere evaluar el riesgo de la central completa y coordinar captaci\u00f3n, bajadas, puesta a tierra, equipotencialidad, protecci\u00f3n contra sobretensiones, apantallamiento, aislamiento, procedimientos de tormenta y <a href=\"https:\/\/saf.uy\/ar\/mantenimiento-inspeccion-pararrayos\/\">mantenimiento<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f1e460d e-con-full e-flex e-con e-child\" data-id=\"f1e460d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-60f4516 elementor-widget-divider--view-line_text elementor-widget-divider--element-align-left elementor-widget elementor-widget-divider\" data-id=\"60f4516\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t\t<h4 class=\"elementor-divider__text elementor-divider__element\">\n\t\t\t\tRESPUESTA R\u00c1PIDA\t\t\t\t<\/h4>\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be289cf elementor-widget elementor-widget-text-editor\" data-id=\"be289cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una central hidroel\u00e9ctrica se protege por capas. El sistema externo intercepta y conduce la corriente del rayo; la puesta a tierra la dispersa y controla diferencias de potencial; la protecci\u00f3n interna limita chispas y sobretensiones; y la operaci\u00f3n mantiene las medidas disponibles mediante inspecciones, pruebas y documentaci\u00f3n. El dise\u00f1o debe considerar cada edificio, subestaci\u00f3n, l\u00ednea, sala de control y servicio auxiliar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-285a5af elementor-widget elementor-widget-text-editor\" data-id=\"285a5af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Por qu\u00e9 una central hidroel\u00e9ctrica es una instalaci\u00f3n cr\u00edtica<\/h2><p>La consecuencia de una falla no se limita al costo de un equipo. Puede afectar la disponibilidad de una unidad generadora, comprometer protecciones, interrumpir comunicaciones, disparar transformadores, detener compuertas o requerir una salida no programada. En instalaciones conectadas al sistema el\u00e9ctrico, un evento local tambi\u00e9n puede tener efectos aguas arriba o aguas abajo de la red.<\/p><p>La evaluaci\u00f3n debe contemplar seguridad de las personas, da\u00f1o f\u00edsico, p\u00e9rdida de servicio, impacto ambiental, recuperaci\u00f3n operativa, repuestos disponibles y tiempo de indisponibilidad. Una peque\u00f1a central de pasada y un gran complejo con embalse no necesitan el mismo proyecto, aunque compartan principios de protecci\u00f3n.<\/p><h2 class=\"codex-docx-preview_heading2\">Qu\u00e9 \u00e1reas deben incluirse en la evaluaci\u00f3n<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c728b7 eael-table-align-center eael-dt-th-align-left elementor-widget elementor-widget-eael-data-table\" data-id=\"2c728b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-data-table.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style>\n\t\t\t@media (max-width: 767px) {\n\t\t\t   #eael-data-table-wrapper-2c728b7.custom-responsive-option-enable .eael-data-table thead {\n                    display: none;\n               }\n               #eael-data-table-wrapper-2c728b7.custom-responsive-option-enable .eael-data-table tbody tr td {\n                    float: none;\n                    clear: left;\n                    width: 100%;\n                    text-align: left;\n                    display: flex;\n                    align-items: center;\n                }\n\t\t\t}\n\t\t\t<\/style>\t\t<div class=\"eael-data-table-wrap custom-responsive-option-enable\" data-table_id=\"2c728b7\" id=\"eael-data-table-wrapper-2c728b7\" data-custom_responsive=\"true\">\n\t\t\t<table class=\"tablesorter eael-data-table center\" id=\"eael-data-table-2c728b7\">\n\t\t\t    <thead>\n\t\t\t        <tr class=\"table-header\">\n\t\t\t\t\t\t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">ZONA<\/span><\/th>\n\t\t\t        \t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">EXPOSICI\u00d3N PRINCIPAL<\/span><\/th>\n\t\t\t        \t\t\t\t            <th class=\" sorting\" id=\"\" colspan=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"data-table-header-text\">MEDIDAS A COORDINAR<\/span><\/th>\n\t\t\t        \t\t\t\t        <\/tr>\n\t\t\t    <\/thead>\n\t\t\t  \t<tbody>\n\t\t\t\t\t\t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCasa de m\u00e1quinas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpacto en cubierta, gr\u00faas, estructuras y penetraciones met\u00e1licas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCaptaci\u00f3n, bajadas, equipotencialidad, separaci\u00f3n y tierra\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tTurbinas y generadores\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tSobretensiones por cables de potencia, excitaci\u00f3n, medici\u00f3n y control\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tDPS, descargadores, apantallamiento, rutas de cables y tierra\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tTransformadores y patio\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpactos directos, ondas viajeras y fallas de aislamiento\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tBlindaje, cables de guarda, descargadores y coordinaci\u00f3n de aislamiento\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tControl y SCADA\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpulsos por alimentaci\u00f3n, datos, antenas y lazos de campo\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tDPS coordinados, fibra, blindajes y equipotencialidad\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tObras exteriores\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tTorres, iluminaci\u00f3n, compuertas, vertederos y estaciones remotas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tCaptaci\u00f3n localizada, tierra, protecci\u00f3n de se\u00f1ales y procedimientos\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t\t\t\t<tr>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tL\u00edneas asociadas\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tImpactos en conductores, cable de guarda y torres\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t   \t\t\t\t\t\t\t\t\t\t\t<td colspan=\"\" rowspan=\"\" class=\"\" id=\"\">\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"td-content-wrapper\"><div class=\"td-content\">\n\t\t\t\t\t\t\t\t\t\t\t\t\tDise\u00f1o de l\u00ednea, puesta a tierra de apoyos y coordinaci\u00f3n con la subestaci\u00f3n\t\t\t\t\t\t\t\t\t\t\t\t<\/div><\/div>\n\t\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/tr>\n\t\t\t        \t\t\t    <\/tbody>\n\t\t\t<\/table>\n\t\t<\/div>\n\t  \t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f71a63 elementor-widget elementor-widget-text-editor\" data-id=\"3f71a63\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 class=\"codex-docx-preview_heading3\">Casa de m\u00e1quinas y estructuras met\u00e1licas<\/h3><p>La cubierta, las gr\u00faas puente, barandas, chimeneas, m\u00e1stiles, conductos y partes salientes pueden convertirse en puntos de captaci\u00f3n o conducir corrientes. El proyecto debe decidir qu\u00e9 elementos pueden utilizarse como componentes naturales y cu\u00e1les necesitan terminales dedicados, garantizando continuidad, secci\u00f3n, uniones y separaci\u00f3n respecto de circuitos sensibles.<\/p><h3 class=\"codex-docx-preview_heading3\">Turbinas, generadores y servicios auxiliares<\/h3><p>El generador puede estar f\u00edsicamente protegido dentro del edificio y aun as\u00ed recibir impulsos por sistemas de excitaci\u00f3n, medici\u00f3n, protecciones, lubricaci\u00f3n, refrigeraci\u00f3n o alimentaci\u00f3n auxiliar. Por eso se revisan todos los caminos conductivos, no solo los cables principales. La coordinaci\u00f3n entre descargadores de media o alta tensi\u00f3n y DPS de baja tensi\u00f3n resulta esencial para evitar que la energ\u00eda residual alcance equipos electr\u00f3nicos.<\/p><h3 class=\"codex-docx-preview_heading3\">Transformadores elevadores y subestaci\u00f3n<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ec6659 elementor-widget elementor-widget-image\" data-id=\"1ec6659\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"563\" src=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-2.webp\" class=\"attachment-full size-full wp-image-8258\" alt=\"Transformadores elevadores y subestaci\u00f3n\" srcset=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-2.webp 1000w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-2-300x169.webp 300w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-2-768x432.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8855660 elementor-widget elementor-widget-text-editor\" data-id=\"8855660\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El patio de maniobras exige un estudio espec\u00edfico de blindaje frente a descargas directas. Cables de guarda, m\u00e1stiles y terminales deben dise\u00f1arse para reducir la exposici\u00f3n de barras y equipos. A la vez, los descargadores de sobretensi\u00f3n y la coordinaci\u00f3n de aislamiento deben limitar las ondas que llegan desde las l\u00edneas o se originan dentro de la instalaci\u00f3n.<\/p><h3 class=\"codex-docx-preview_heading3\">Control, comunicaciones y estaciones remotas<\/h3><p>Los rel\u00e9s digitales, PLC, servidores, redes industriales, teleprotecci\u00f3n, antenas, CCTV y sensores trabajan con niveles de energ\u00eda peque\u00f1os. Un impulso puede no destruir el equipo inmediatamente, pero provocar reinicios, errores intermitentes o p\u00e9rdida de datos. El dise\u00f1o interno debe revisar blindajes, entradas de cables, enlaces de cobre, fibra \u00f3ptica, alimentaci\u00f3n continua y referencias de tierra.<\/p><h2 class=\"codex-docx-preview_heading2\">Las cinco capas de una protecci\u00f3n eficaz<\/h2><h3 class=\"codex-docx-preview_heading3\">1. Evaluaci\u00f3n del riesgo<\/h3><p>El punto de partida es identificar la amenaza, la geometr\u00eda, los servicios conectados y las consecuencias de una falla. La serie IRAM 2184 \/ AEA 92305 organiza la evaluaci\u00f3n y las medidas para estructuras, personas y sistemas el\u00e9ctricos y electr\u00f3nicos. En una central, el an\u00e1lisis se complementa con las especificaciones del operador, las normas de alta tensi\u00f3n y los criterios de confiabilidad del proyecto.<\/p><h3 class=\"codex-docx-preview_heading3\">2. Sistema externo de protecci\u00f3n<\/h3><p>La captaci\u00f3n puede resolverse mediante terminales, mallas, cables de guarda o elementos met\u00e1licos aptos. Las bajadas conducen la corriente por recorridos definidos hasta tierra. El m\u00e9todo de dise\u00f1o debe demostrar el volumen protegido y evitar trayectorias improvisadas, curvas innecesarias o proximidad peligrosa con canalizaciones, combustible y equipos sensibles.<\/p><h3 class=\"codex-docx-preview_heading3\">3. Puesta a tierra y equipotencialidad<\/h3><p>La central suele tener una malla extensa vinculada con generadores, transformadores, estructuras y subestaciones. La protecci\u00f3n contra rayos debe integrarse con esa red sin crear tierras aisladas que puedan alcanzar potenciales diferentes. La resistividad, el estado de las uniones, la corrosi\u00f3n y las tensiones de paso y contacto importan m\u00e1s que perseguir un n\u00famero \u00fanico de resistencia.<\/p><h3 class=\"codex-docx-preview_heading3\">4. Sobretensiones y coordinaci\u00f3n de aislamiento<\/h3><p>Los descargadores de media y alta tensi\u00f3n, los DPS de tableros, las protecciones de se\u00f1ales y el apantallamiento deben trabajar como un conjunto. La selecci\u00f3n considera tensi\u00f3n permanente, nivel de protecci\u00f3n, corriente de descarga, energ\u00eda, ubicaci\u00f3n, longitud de conexiones y capacidad soportable del equipo. En patios y l\u00edneas, la coordinaci\u00f3n de aislamiento se vincula con los niveles de impulso de transformadores, interruptores y barras.<\/p><h3 class=\"codex-docx-preview_heading3\">5. Operaci\u00f3n, alerta y mantenimiento<\/h3><p>La ingenier\u00eda se completa con procedimientos para tormentas, restricciones de trabajos exteriores, gesti\u00f3n de alarmas, inspecci\u00f3n posterior a eventos y pruebas peri\u00f3dicas. Contadores de descargas, sistemas de detecci\u00f3n o informaci\u00f3n meteorol\u00f3gica pueden aportar evidencia, pero no reemplazan la inspecci\u00f3n f\u00edsica y el\u00e9ctrica.<\/p><h2 class=\"codex-docx-preview_heading2\">C\u00f3mo se desarrolla un proyecto<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d73df96 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"d73df96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Relevamiento de planos, unifilares, sistemas existentes, registros de fallas y criticidad de activos. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"> Inspecci\u00f3n de captaci\u00f3n, bajadas, malla de tierra, subestaci\u00f3n, tableros, cableados y comunicaciones.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Evaluaci\u00f3n del riesgo y definici\u00f3n de zonas de protecci\u00f3n externa e interna.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"> Ingenier\u00eda de detalle con planos, memoria, materiales, coordinaci\u00f3n de protecciones y secuencia de obra.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"> Montaje dentro de ventanas operativas compatibles con seguridad y disponibilidad.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"> Ensayos de continuidad, puesta a tierra, equipotencialidad, inspecci\u00f3n visual y verificaci\u00f3n documental. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Entrega de planos conforme a obra, informe, recomendaciones y plan de mantenimiento.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b914bc elementor-widget elementor-widget-image\" data-id=\"6b914bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"563\" src=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-3.webp\" class=\"attachment-full size-full wp-image-8259\" alt=\"SAF en Hidroel\u00e9ctrica Itaip\u00fa\" srcset=\"https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-3.webp 1000w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-3-300x169.webp 300w, https:\/\/saf.uy\/ar\/wp-content\/uploads\/hidroelectrica-itaipu-3-768x432.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" title=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d249f61 elementor-widget elementor-widget-text-editor\" data-id=\"d249f61\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">Contexto argentino y referencias t\u00e9cnicas<\/h2><p>Argentina posee centrales de embalse y de pasada en regiones con condiciones muy diferentes. En Comahue y Patagonia se combinan grandes obras, clima fr\u00edo, viento y distancias extensas; en Litoral y NEA aparecen alta humedad y tormentas asociadas a grandes r\u00edos; Cuyo y NOA suman relieve, sequedad, polvo y amplitud t\u00e9rmica. La soluci\u00f3n debe adaptarse a la ubicaci\u00f3n y no copiarse entre plantas.<\/p><p>Como referencia nacional, la serie IRAM 2184 \/ AEA 92305 aborda principios generales, evaluaci\u00f3n del riesgo, da\u00f1o f\u00edsico y protecci\u00f3n de sistemas el\u00e9ctricos y electr\u00f3nicos. Para subestaciones, l\u00edneas y alta tensi\u00f3n pueden sumarse normas y gu\u00edas internacionales como IEEE 998 e IEC 60071, siempre dentro de las exigencias contractuales, regulatorias y del operador. Debe verificarse la edici\u00f3n vigente antes de dise\u00f1ar o publicar.<\/p><h2 class=\"codex-docx-preview_heading2\">Mantenimiento e inspecci\u00f3n en una central operativa<\/h2><p>El plan debe diferenciar inspecci\u00f3n visual, verificaci\u00f3n completa y revisi\u00f3n despu\u00e9s de impactos, ampliaciones, fallas o intervenciones civiles. Se controlan corrosi\u00f3n, uniones, conductores, soportes, cajas de inspecci\u00f3n, continuidad, estado de descargadores y DPS, indicadores, registros de eventos y modificaciones no reflejadas en planos.<\/p><p>Las obras de modernizaci\u00f3n suelen cambiar rutas de cable, tableros, antenas, sistemas de control y estructuras. Cada cambio debe activar una revisi\u00f3n del esquema de protecci\u00f3n para evitar que la instalaci\u00f3n real se aleje del dise\u00f1o original.<\/p><h2 class=\"codex-docx-preview_heading2\">Errores frecuentes<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6846cd elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"a6846cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Proteger solo el edificio principal y omitir subestaci\u00f3n, l\u00edneas, compuertas o estaciones remotas. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Agregar terminales sin verificar el recorrido de corriente y la integraci\u00f3n con la malla de tierra. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Instalar DPS sin coordinaci\u00f3n, con conexiones largas o sin revisar la tensi\u00f3n del sistema.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Conectar blindajes, neutros y tierras de forma inconsistente entre control y potencia.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Usar planos desactualizados o no registrar modificaciones realizadas durante paradas de planta.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Elegir tecnolog\u00eda por radio comercial sin an\u00e1lisis del riesgo ni validaci\u00f3n del proyecto.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d7968a elementor-widget elementor-widget-text-editor\" data-id=\"7d7968a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Evaluaci\u00f3n t\u00e9cnica de SAF para la Hidroel\u00e9ctrica de Itaip\u00fa<\/h2><p>SAF elabor\u00f3 un <strong>informe t\u00e9cnico orientado a evaluar alternativas para reforzar la protecci\u00f3n contra descargas atmosf\u00e9ricas de la Hidroel\u00e9ctrica de Itaip\u00fa<\/strong>, uno de los complejos de generaci\u00f3n m\u00e1s relevantes de Sudam\u00e9rica. El an\u00e1lisis puso especial atenci\u00f3n en puntos cr\u00edticos como las l\u00edneas de transmisi\u00f3n, las subestaciones, la casa de m\u00e1quinas y el sistema de puesta a tierra, identificando posibles \u00e1reas de intervenci\u00f3n y tecnolog\u00edas que podr\u00edan complementar la protecci\u00f3n existente.<\/p><p>La central ya dispone de m\u00faltiples capas de protecci\u00f3n, entre ellas puntas Franklin y mallas conductoras en edificios, cables de guarda sobre l\u00edneas de alta tensi\u00f3n, descargadores de sobretensi\u00f3n, una red de puesta a tierra de gran escala y sistemas autom\u00e1ticos de protecci\u00f3n y control. Esta arquitectura permite aislar fallas y limitar sus consecuencias, aunque los antecedentes de tormentas muestran que las descargas sobre l\u00edneas asociadas pueden provocar desconexiones preventivas y afectar temporalmente la disponibilidad de generaci\u00f3n.<\/p><p>A partir de este an\u00e1lisis, SAF plante\u00f3 <strong>posibles soluciones de mejora y complementaci\u00f3n<\/strong>, sujetas a estudios de detalle, validaci\u00f3n t\u00e9cnica y eventual aprobaci\u00f3n por parte del operador antes de cualquier implementaci\u00f3n.<\/p><h3 class=\"codex-docx-preview_heading3\">Qu\u00e9 puntos analiz\u00f3 SAF para reforzar la protecci\u00f3n<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a5c9a5 elementor-icon-list--layout-traditional elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"1a5c9a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><B>Torres de salida de alta tensi\u00f3n<\/B>, por su exposici\u00f3n y por el efecto que una falla transitoria puede tener sobre las l\u00edneas vinculadas a la central.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><B>P\u00f3rticos de subestaci\u00f3n y estructuras asociadas a interruptores y transformadores<\/B>, donde deben coordinarse protecci\u00f3n externa, descargadores, aislamiento y puesta a tierra.  <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><B>Casa de m\u00e1quinas y edificio de producci\u00f3n<\/B>, con especial atenci\u00f3n a los puntos altos, los sistemas de control y los caminos por los que una sobretensi\u00f3n puede ingresar a equipos sensibles. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><B>Sistema de puesta a tierra y bases de torres cr\u00edticas<\/B>, considerando la elevada resistividad del terreno y la necesidad de controlar la impedancia y la circulaci\u00f3n de corrientes impulsivas. <\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-dot-circle\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><B>Estado de los sistemas existentes<\/B>, para determinar si una modernizaci\u00f3n puede aprovechar bajadas, conductores y conexiones a tierra que conserven continuidad y buenas condiciones.<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ea9aec elementor-widget elementor-widget-text-editor\" data-id=\"8ea9aec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Tecnolog\u00edas consideradas en la propuesta<\/h3><p>Dentro del an\u00e1lisis realizado para Itaip\u00fa, SAF evalu\u00f3 <strong>posibles alternativas para complementar la protecci\u00f3n existente<\/strong>, entre ellas la eventual incorporaci\u00f3n de sistemas PPDA en puntos estrat\u00e9gicos y el uso de <a href=\"https:\/\/saf.uy\/ar\/productos\/filtros-de-tierra\/\">filtros de tierra Earth Stroke TRZ 95<\/a> en sectores expuestos a sobretensiones y corrientes impulsivas.<\/p><p>Estas tecnolog\u00edas fueron planteadas como <strong>opciones sujetas a evaluaci\u00f3n t\u00e9cnica<\/strong>, no como soluciones ya instaladas ni como reemplazos autom\u00e1ticos de los sistemas actuales. Su eventual aplicaci\u00f3n depender\u00eda del an\u00e1lisis de riesgo, la compatibilidad con las protecciones existentes, el estado de la puesta a tierra, las condiciones particulares de cada sector y la aprobaci\u00f3n t\u00e9cnica del operador.<\/p><p>El estudio realizado sobre Itaip\u00fa tambi\u00e9n permite extraer una conclusi\u00f3n aplicable a centrales hidroel\u00e9ctricas de gran escala: la protecci\u00f3n contra rayos debe abordarse como un sistema coordinado. Captaci\u00f3n, l\u00edneas, subestaciones, puesta a tierra, automatizaci\u00f3n y respuesta operativa deben analizarse en conjunto para identificar oportunidades de mejora y evitar que una intervenci\u00f3n aislada genere nuevos puntos vulnerables.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3050b5e elementor-widget elementor-widget-text-editor\" data-id=\"3050b5e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"codex-docx-preview_heading2\">C\u00f3mo puede intervenir SAF Argentina<\/h2><p>SAF puede participar en evaluaci\u00f3n de riesgo, relevamiento, consultor\u00eda, ingenier\u00eda, provisi\u00f3n e instalaci\u00f3n de sistemas Franklin, PDC o <a href=\"https:\/\/saf.uy\/ar\/productos\/pararrayos-inhibidor-zeus\/\">PPDA<\/a>, soluciones de puesta a tierra, protecci\u00f3n complementaria e inspecci\u00f3n. En instalaciones hidroel\u00e9ctricas, el alcance debe definirse junto con las \u00e1reas de generaci\u00f3n, subestaciones, control y seguridad de la planta.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f006582 content-align-cta-default elementor-widget elementor-widget-eael-cta-box\" data-id=\"f006582\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-cta-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"eael-call-to-action cta-basic bg-lite cta-preset-1\">\n        <h2 class=\"title eael-cta-heading\">Solicite una evaluaci\u00f3n t\u00e9cnica<\/h2><p>Env\u00ede ubicaci\u00f3n, potencia, planos generales y unifilares, fotograf\u00edas, altura de estructuras, datos de la subestaci\u00f3n, antecedentes de impactos y restricciones de acceso. SAF Argentina podr\u00e1 proponer una revisi\u00f3n documental, una visita o un estudio por etapas desde su oficina en la Ciudad de Buenos Aires, con atenci\u00f3n a proyectos de distintas regiones del pa\u00eds.<\/p><a href=\"https:\/\/saf.uy\/ar\/contacto\/\" class=\"cta-button cta-preset-1  \">Cont\u00e1ctenos<\/a>\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5d33bd elementor-widget elementor-widget-heading\" data-id=\"f5d33bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preguntas Frecuentes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f7cfe8e elementor-widget elementor-widget-n-accordion\" data-id=\"f7cfe8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2590\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-2590\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfUn solo pararrayos puede proteger toda la central? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2590\" class=\"elementor-element elementor-element-173da4f e-con-full e-flex e-con e-child\" data-id=\"173da4f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2590\" class=\"elementor-element elementor-element-855b4a1 e-flex e-con-boxed e-con e-child\" data-id=\"855b4a1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f0228ea elementor-widget elementor-widget-text-editor\" data-id=\"f0228ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No necesariamente. La central est\u00e1 formada por edificios, patios, l\u00edneas y sistemas conectados. El volumen protegido y los caminos de corriente deben demostrarse para cada zona.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2591\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2591\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfLa malla de tierra de la subestaci\u00f3n sirve para el sistema de pararrayos? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2591\" class=\"elementor-element elementor-element-80212c6 e-con-full e-flex e-con e-child\" data-id=\"80212c6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2591\" class=\"elementor-element elementor-element-3e3b8a4 e-flex e-con-boxed e-con e-child\" data-id=\"3e3b8a4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0f5bc8a elementor-widget elementor-widget-text-editor\" data-id=\"0f5bc8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Puede formar parte del sistema integrado si el dise\u00f1o, la continuidad, las uniones y las tensiones de paso y contacto son adecuadas. No debe asumirse sin verificaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2592\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2592\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfC\u00f3mo se protegen los PLC y el sistema SCADA? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2592\" class=\"elementor-element elementor-element-ad108e7 e-con-full e-flex e-con e-child\" data-id=\"ad108e7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2592\" class=\"elementor-element elementor-element-f15632c e-flex e-con-boxed e-con e-child\" data-id=\"f15632c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09cf21d elementor-widget elementor-widget-text-editor\" data-id=\"09cf21d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Con zonificaci\u00f3n, equipotencialidad, apantallamiento, rutas de cables, enlaces de fibra cuando corresponda y DPS coordinados en energ\u00eda, datos y se\u00f1ales.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2593\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2593\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 tecnolog\u00eda de captaci\u00f3n conviene en una hidroel\u00e9ctrica? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2593\" class=\"elementor-element elementor-element-a60a88a e-con-full e-flex e-con e-child\" data-id=\"a60a88a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2593\" class=\"elementor-element elementor-element-a8f39ab e-flex e-con-boxed e-con e-child\" data-id=\"a8f39ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-db3888f elementor-widget elementor-widget-text-editor\" data-id=\"db3888f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La decisi\u00f3n depende de la evaluaci\u00f3n del riesgo, geometr\u00eda, ambiente, normativa y especificaciones del operador. Franklin, PDC o PPDA deben evaluarse dentro del sistema completo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2594\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2594\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfEs necesario revisar la instalaci\u00f3n despu\u00e9s de una tormenta? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2594\" class=\"elementor-element elementor-element-9ae6ed6 e-con-full e-flex e-con e-child\" data-id=\"9ae6ed6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2594\" class=\"elementor-element elementor-element-3aeca07 e-flex e-con-boxed e-con e-child\" data-id=\"3aeca07\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6361e6f elementor-widget elementor-widget-text-editor\" data-id=\"6361e6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed cuando hubo impacto registrado, disparos, alarmas, fallas o indicios de da\u00f1o. Tambi\u00e9n corresponde revisar despu\u00e9s de obras, ampliaciones o cambios en la cubierta y cableados.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2595\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2595\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfQu\u00e9 documentos debe entregar el proyecto? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2595\" class=\"elementor-element elementor-element-ded8412 e-flex e-con-boxed e-con e-child\" data-id=\"ded8412\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2595\" class=\"elementor-element elementor-element-01edf27 e-con-full e-flex e-con e-child\" data-id=\"01edf27\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-94a43a9 elementor-widget elementor-widget-text-editor\" data-id=\"94a43a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Memoria, evaluaci\u00f3n, planos, especificaciones, c\u00e1lculos, protocolos de pruebas, fotograf\u00edas, planos conforme a obra, manual y plan de mantenimiento.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-2596\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-2596\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> \u00bfSAF puede trabajar en centrales existentes? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><i aria-hidden=\"true\" class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t<span class='e-closed'><i aria-hidden=\"true\" class=\"fas fa-plus\"><\/i><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2596\" class=\"elementor-element elementor-element-520e035 e-flex e-con-boxed e-con e-child\" data-id=\"520e035\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-2596\" class=\"elementor-element elementor-element-0c80f09 e-con-full e-flex e-con e-child\" data-id=\"0c80f09\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-19009f4 elementor-widget elementor-widget-text-editor\" data-id=\"19009f4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00ed. El alcance puede comenzar con una auditor\u00eda del sistema instalado, identificaci\u00f3n de brechas y un plan de mejoras priorizado seg\u00fan criticidad y ventanas operativas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Gu\u00eda para proteger centrales hidroel\u00e9ctricas en Argentina: riesgo, captaci\u00f3n, puesta a tierra, sobretensiones, subestaciones y mantenimiento. <\/p>\n","protected":false},"author":1,"featured_media":8253,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":"","_joinchat":[],"footnotes":""},"categories":[33,4],"tags":[289,291,283,282,288,290,284,287,285,286],"class_list":["post-8250","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-noticias","tag-descargadores-de-sobretension","tag-mantenimiento-de-sistemas-de-proteccion-contra-rayos","tag-pararrayos-para-centrales-hidroelectricas","tag-proteccion-contra-rayos-en-centrales-hidroelectricas","tag-proteccion-de-casa-de-maquinas","tag-proteccion-de-lineas-de-transmision","tag-proteccion-de-subestaciones-contra-rayos","tag-proteccion-de-transformadores-electricos","tag-puesta-a-tierra-en-centrales-hidroelectricas","tag-sobretensiones-en-centrales-hidroelectricas"],"acf":[],"_links":{"self":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8250","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/comments?post=8250"}],"version-history":[{"count":17,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8250\/revisions"}],"predecessor-version":[{"id":8299,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/posts\/8250\/revisions\/8299"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/media\/8253"}],"wp:attachment":[{"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/media?parent=8250"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/categories?post=8250"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/saf.uy\/ar\/wp-json\/wp\/v2\/tags?post=8250"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}